You are here: International     Ammann international
    EB
Max. continuous output with 3% humidity without RA proportion  t/h  90
Max. continuous output with 5% humidity without RA proportion  t/h  70
Aggregate pre-dosing     
Number of feeder ADL    2 + 2
Contents  m³  24
Drier drum     
Type designation    1410 /1650
Length  6.5
Diameter  1.41 / 1.65
Burner output  MW  6.5
Fuels    Natural gas,LPG gasified, Fuel oil extra light, heavy oil,combi gas/fuel
Drum drive  kW  4 x 4
Output with 3% humidity  t/h  90
Output with 5% humidity  t/h  75
Dust extraction filter     
Extraction output  Nm³/h  21000
Filter area  m²  330
Mixing tower     
Screening    4 fractions + bypass
Screening machine type    VS 1440
Screen surface  m²  10.5
Hot aggregate silo 1-row  10
Hot aggregate silo 2-row   
Aggregate weighing scale  kg  1600
Filler weighing scale  kg   
Bitumen weighing scale  kg   
Effective mixer capacity  1.2
Maximum mixer output  t/h  90
Bitumen supply    1 hot oil heated tank 25 m3
Filler supply    Standard: reclaimed filler silo 29 m3.Optional imported filler silo 52 m3 with reclaimed filler silo increased to 41 m3
Integrated charging silo Content/Number of chambers    Direct loading, 30 t / 1 Content or lateral 57 t / 1 Content ,76 t / 2 Content,120 t / 2 Content
Cold addition up to 25%    Recommendation: directly into the mixer. Alternative into hot elevator
Hot addition up to 50%     
Hot addition to 50%