You are here: International     Ammann international
Uniglobe 200-320 t/h
Uniglobe 200-320 t/h
    Uniglobe 200 t/hUniglobe 320 t/h
Max. continuous output with 5% humidity without RA proportion  t/h  200320 
Aggregate pre-dosing      
Number of feeder ADL    Any numberAny number 
Contents  m³  10, 12 or 1410, 12 or 14 
Drier drum      
Type designation    T 2290T 27100 
Length  9.010.0 
Diameter  2.22.7 
Burner output  MW  15.524.0 
Fuels    Natural gas, extra-light heating oil, heavy oil, liquid gas, brown coal dust (BCD)Natural gas, extra-light heating oil, heavy oil, liquid gas, brown coal dust (BCD) 
Drum drive  kW  4 x 154 x 18.5 
Dust extraction filter      
Filter type    AFA 48AFA77 
Filter area  m²  7371179 
Mixing tower      
Screening    4-, 5- or 6-fold4-, 5- or 6-fold 
Screening machine type    VA 1840VA 2060 
Screen surface  m²  31 (screening 6-fold)56 (screening 6-fold) 
Hot aggregate silo 1-row  56 or 80 (max. 7 chambers) 
Hot aggregate silo 2-row  -
Aggregate weighing scale  kg  30004000 
Filler weighing scale  kg  300/400400 
Bitumen weighing scale  kg  315315 
Effective mixer capacity  3
Maximum mixer output (80 t/Ch.)  t/h  240320 
Bitumen supply    E-Bit, horizontal or vertical designE-Bit, horizontal or vertical design 
Filler supply    As per customer specification: proprietary and external filler supply or filler silosAs per customer specification: proprietary and external filler supply or filler silos 
Integrated charging silo Content/Number of chambers    50 t (2 chambers; 21/5/21), 100 t (2 chambers; 45/10/45), 200 t (4 chambers; 45/10/45/52/52)50 t (2 chambers; 21/5/21), 100 t (2 chambers; 45/10/45), 200 t (4 chambers; 45/10/45/52/52) 
Cold addition up to 30%    Recommendation: directly into the mixer; alternatively: in the hot elevator or via admixing ring into the drier drum (up to 20 %)Recommendation: directly into the mixer; alternatively: in the hot elevator or via admixing ring into the drier drum (up to 20 %) 
Hot addition up to 60%    Hot oil heated tanks horizontal 35-50-67 m3
Hot addition up to 100%    Hot oil heated tanks horizontal 35-50-67 m3 
    
Uniglobe 200-320 t/h

Uniglobe 200 t/h Compare to

Uniglobe 240 t/h