Uniglobe 320 t/h | Uniglobe 240 t/h |
|
Max. continuous output with 5% humidity without RA proportion |
t/h |
320 | 240 |
| Aggregate pre-dosing |
|
| |
|
Number of feeder ADL |
|
Any number | Any number |
|
Contents |
m³ |
10, 12 or 14 | 10, 12 or 14 |
| Drier drum |
|
| |
|
Type designation |
|
T 27100 | T2590 |
|
Length |
m |
10.0 | 9.0 |
|
Diameter |
m |
2.7 | 2.5 |
|
Burner output |
MW |
24.0 | 20.0 |
|
Fuels |
|
Natural gas, extra-light heating oil, heavy oil, liquid gas, brown coal dust (BCD) | Natural gas, extra-light heating oil, heavy oil, liquid gas, brown coal dust (BCD) |
|
Drum drive |
kW |
4 x 18.5 | 4 x 15 |
| Dust extraction filter |
|
| |
|
Filter type |
|
AFA77 | AFA 57 |
|
Filter area |
m² |
1179 | 884 |
| Mixing tower |
|
| |
|
Screening |
|
4-, 5- or 6-fold | 4-, 5- or 6-fold |
|
Screening machine type |
|
VA 2060 | VA 2050 |
|
Screen surface |
m² |
56 (screening 6-fold) | 43.5 (screening 6-fold) |
|
Hot aggregate silo 1-row |
t |
| 56 or 80 (max. 7 chambers) |
|
Hot aggregate silo 2-row |
t |
- | - |
|
Aggregate weighing scale |
kg |
4000 | 3000 |
|
Filler weighing scale |
kg |
400 | 300/400 |
|
Bitumen weighing scale |
kg |
315 | 315 |
|
Effective mixer capacity |
t |
4 | 3 |
|
Maximum mixer output (80 t/Ch.) |
t/h |
320 | 240 |
|
Bitumen supply |
|
E-Bit, horizontal or vertical design | E-Bit, horizontal or vertical design |
|
Filler supply |
|
As per customer specification: proprietary and external filler supply or filler silos | As per customer specification: proprietary and external filler supply or filler silos |
|
Integrated charging silo Content/Number of chambers |
|
50 t (2 chambers; 21/5/21), 100 t (2 chambers; 45/10/45), 200 t (4 chambers; 45/10/45/52/52) | 50 t (2 chambers; 21/5/21), 100 t (2 chambers; 45/10/45), 200 t (4 chambers; 45/10/45/52/52) |
|
Cold addition up to 30% |
|
Recommendation: directly into the mixer; alternatively: in the hot elevator or via admixing ring into the drier drum (up to 20 %) | Recommendation: directly into the mixer; alternatively: in the hot elevator or via admixing ring into the drier drum (up to 20 %) |
|
Hot addition up to 60% |
|
- | - |
|
Hot addition up to 100% |
|
| |