SB 180 | SB 280 |
|
Max. continuous output with 3% humidity without RA proportion |
t/h |
180 | 280 |
|
Max. continuous output with 5% humidity without RA proportion |
t/h |
170 | 240 |
| Aggregate pre-dosing |
|
| |
|
Number of feeder ADL |
|
Various | Various |
|
Contents |
m³ |
14-19 | 14-19 |
| Drier drum |
|
| |
|
Type designation |
|
ES 2390 | ES 25100 |
|
Length |
m |
9.0 | 10.0 |
|
Diameter |
m |
2.3 | 2.5 |
|
Burner output |
MW |
13.9 | 20.0 |
|
Fuels |
|
Natural gas,LPG gasified, Fuel oil extra light, heavy oil,combi gas/fuel | Natural gas,LPG gasified, Fuel oil extra light, heavy oil,combi gas/fuel |
|
Drum drive |
kW |
4 x 15 | 4 x 18.5 |
|
Output with 3% humidity |
t/h |
245 | 297 |
|
Output with 5% humidity |
t/h |
196 | 237 |
| Dust extraction filter |
|
| |
|
Extraction output |
Nm³/h |
43000 | 57000 |
|
Filter area |
m² |
675 | 900 |
| Mixing tower |
|
| |
|
Screening |
|
4-, 5- or 6-fold | 4-, 5- or 6-fold |
|
Screening machine type |
|
VA 1840 | VA 2050 |
|
Screen surface |
m² |
31.0 | 43.5 |
|
Hot aggregate silo 1-row |
t |
30 to 78 (max 7 compartments) | 43 to 96 (max 7 compartments) |
|
Hot aggregate silo 2-row |
t |
| |
|
Aggregate weighing scale |
kg |
2560 | 3680 |
|
Filler weighing scale |
kg |
242 | 440 |
|
Bitumen weighing scale |
kg |
285 | 399 |
|
Effective mixer capacity |
t |
2.1 | 3.3 |
|
Maximum mixer output |
t/h |
168-189 | 264-297 |
|
Bitumen supply |
|
Hot oil heated tanks horizontal 35-50-67 m3 | Bitumen horizontal 35-50-67 m³ (depending on the contracts) |
|
Filler supply |
|
Standard: reclaimed filler silo 25 m3.Optional imported filler silo 46 m3 with reclaimed filler silo increased to 36 m3 | Standard: reclaimed filler silo 29 m3.Optional imported filler silo 52 m3 with reclaimed filler silo increased to 41 m3 |
|
Integrated charging silo Content/Number of chambers |
|
Direct loading, 30 t / 1 Content or lateral 57 t / 1 Content ,76 t / 2 Content,120 t / 2 Content | Direct loading, 30 t / 1 Content or lateral 57 t / 1 Content ,76 t / 2 Content,120 t / 2 Content |
|
Cold addition up to 25% |
|
Recommendation: directly into the mixer. Alternative into hot elevator | Recommendation: directly into the mixer. Alternative into hot elevator |
|
Hot addition up to 50% |
|
With drier Drum RAH50/2390 via ring | With drier Drum RAH50/25100 via ring |
|
Hot addition to 50% |
|
via parallel drum system | via parallel drum system |